SMX2000LVNC - APC Smart-UPS X 2000VA Short Depth Tower/Rack Convertible LCD 100-127V with Network Card

APC

(No reviews yet) Write a Review
MSRP: $3,380.00
$2,174.00
(You save $1,206.00 )
SKU:
SMX2000LVNC
Weight:
105.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Product Overview

APC Smart-UPS X 2000VA Short Depth Tower/Rack Convertible LCD 100-127V with Network Card Features

APC Smart-UPS, 1800 Watts /1920 VA, Input 120V /Output 120V, Interface Port RJ-45 Serial, USB, Extended runtime model, Rack Height 4 U

Includes: CD with software, Documentation CD, Installation guide, Network Management Card, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable

StruxureWare Central compatible 
Enables centralized management via StruxureWare Central.
APC USB communications 
Enables communication with Smart-UPS RTD, SMX and SMT using the APC's historical proprietary USB usages
Boost and Trim Automatic Voltage Regulation (AVR) 
Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
Serial connectivity 
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
High online efficiency 
Reduces utlility costs, generates less heat.
Green mode 
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High frequency design 
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
Energy meter 
Provides actual kilowatt hours of usage for energy conscious users.
Predictive replace battery date 
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Intuitive LCD interface 
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Auto recognition of external batteries 
UPS recognizes when external battery packs are attached and automatically adjusts runtime.
Multiple switched outlet groups 
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
Pure sine wave output on battery 
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Preinstalled network management card 
Provides for remote management and control of the UPS over a network out of the box.
Disconnected battery notification 
Warns when a battery is not available to provide backup power.
Load shedding 
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).
Sequenced network shutdown and reboot 
Customize network shutdown and reboot sequence of connected servers and UPSs.
Outlet group control 
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
Scalable runtime 
Allows additional run time to be quickly added as needed.
Adjustable voltage sensitivity 
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points 
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms 
Provides notification of changing utility power and UPS power conditions
Automatic restart of loads after UPS shutdown 
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test 
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable 
Provides temporary battery power when the utility power is out.
Hot-swappable batteries 
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Multiple mounting methods 
Allows for standardization on one product for use in different environments.
Network manageable 
Provides remote power management of the UPS over the network.
Battery failure notification 
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Rack/Tower convertible 
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Safety-agency approved 
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serial connectivity 
Provides management of the UPS via a serial port.
Temperature-compensated battery charging 
Prolongs battery life by regulating the charge voltage according to battery temperature.
USB connectivity 
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries 
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Boost and Trim Automatic Voltage Regulation (AVR) 
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
 
 
Output Connections:
 
(6) NEMA 5-15R
 
NEMA 5-15R
 
(3) NEMA 5-20R
 
NEMA 5-20R
 
(1) NEMA L5-20R
 
NEMA L5-20R
 
Input Connections:
 
NEMA 5-20P
 
NEMA 5-20P
 
Availability
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
 
Manageability
Network manageable
Provides remote power management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
 
Serviceability
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
 
Adaptability
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
 
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
 

Reviews

(No reviews yet) Write a Review